Signal Injectors


Injection Transformers

ModelTBJT01TBJT02TBJT03TBJT04
ApplicationBode measurementsBode measurementsImmunity testingCS101 immunity test
PSU impedance measurements
Impedance50 Ω50 Ω50 Ω4:1 (e.g. 2 Ω : 0.5 Ω)
Frequency range10 Hz – 45 MHz1 Hz – 7 MHz50 kHz – 50 MHz1 kHz – 50 MHz
Internal termination resistor5 Ω5 Ωn.a.; built in HPF to
suppress 50/60/400 Hz
n.a.
Fuse125 mA polyfuse;
secondary (output) side
125 mA polyfuse;
secondary (output) side
n.a. secondary capacitively
decoupled with Y-capacitor
n.a.;AC/DC saturation current
secondary:>60A Voltage rating 250V AC/DC
Isolation test: 1500 V DC
Dimensions70 mm x 60 mm x 140 mm70 mm x 60 mm x 140 mm70 mm x 60 mm x 140 mm215 mm x 160 mm x 350 mm, 16 kg
Product PageTBJT01TBJT02TBJT03TBJT04

Bulk Current Injection Probes

Bulk Current Injection Probes are used to inject RF-current into cables of electrical equipment to test the susceptibility against radiated electromagnetic energy. Tekbox BCI-probes can be clamped around wire bundles with up to 27 mm. They are designed to meet the specifcations of the standards IC 61000-4-6 (domestic and industrial products) and ISO 11452-4 (automotive products).

Tekbox supplies suitable wideband power amplifiers to drive the BCI probes:

TBMDA-CDN25 for immunity tests according to IC 61000-4-6
TBMDA-BCI25 for immunity tests according to ISO 11452-4

The calibration fixture TBBCI1-CAL is suitable for both BCI-probe models

ModelTBBCI1-200K280TBBCI1-300K420-HVTBBCI1-800K420TBBCI1-CAL
Frequency range150 kHz – 230 MHz300 kHz – 400 MHz1 MHz – 400 MHz150 kHz – 400 MHz
Coupling loss8 dB typical5 dB typical5 dB typical
Maximum RF input power50W continuous
100W short time
50W continuous
100W short time
50W continuous
100W short time
500 W
Aperture diameter27 mm27 mm27 mm
Outer dimensions92 x 76 mm92 x 76 mm92 x 76 mm200 × 150 × 140 mm
Application / StandardBCI probe for IEC / ISO 61000-6-4BCI probe for ISO 11452-4; MIL-STD-461 CS114, GJB 151B-2013, DO-160BCI probe for IEC / ISO 11452-4BCI probe calibrator for IC / ISO 61000-6-4
IEC / ISO 11452-4
Product PageTBBCI1-200K280TBBCI1-300K420-HVTBBCI1-800K420TBBCI1-CAL

Bias Tee

ModelTBBT01
Usable frequency range5 kHz – 1.2 GHz
RF path insertion loss<1 dB typ. in the range 10 kHz – 1 GH
< 1.5 dB in the range 5 kHz – 1.2 GHz
VSWR1 < VSWR < 2 in the range 5 kHz to 1 GHz
Characterized frequency range1 kHz -3 GHz
RF power handling50 W from 5 kHz – 1 GHz
Operating voltage rangemax. ±100 V
Operating current range± 5A DC continuous, max. ± 15 A DC
Product PageTBBT01

Trans-conductance Amplifier/Current Injector

ModelTBRFCI1
Frequency RangeDC – 50 MHz, useable up to 100 MHz
Transconductance0.1 A/V, 1 A/V
Product PageTBRFCI1