Signal Injectors
Injection Transformers
Bulk Current Injection Probes
Bias Tee
Trans-conductance Amplifier/Current Injector
Bulk Current Injection Probes
Bias Tee
Trans-conductance Amplifier/Current Injector
Injection Transformers
![]() | ![]() | ![]() | ![]() |
|
|---|---|---|---|---|
| Model | TBJT01 | TBJT02 | TBJT03 | TBJT04 |
| Application | Bode measurements | Bode measurements | Immunity testing | CS101 immunity test PSU impedance measurements |
| Impedance | 50 Ω | 50 Ω | 50 Ω | 4:1 (e.g. 2 Ω : 0.5 Ω) |
| Frequency range | 10 Hz – 45 MHz | 1 Hz – 7 MHz | 50 kHz – 50 MHz | 1 kHz – 50 MHz |
| Internal termination resistor | 5 Ω | 5 Ω | n.a.; built in HPF to suppress 50/60/400 Hz | n.a. |
| Fuse | 125 mA polyfuse; secondary (output) side | 125 mA polyfuse; secondary (output) side | n.a. secondary capacitively decoupled with Y-capacitor | n.a.;AC/DC saturation current secondary:>60A Voltage rating 250V AC/DC Isolation test: 1500 V DC |
| Dimensions | 70 mm x 60 mm x 140 mm | 70 mm x 60 mm x 140 mm | 70 mm x 60 mm x 140 mm | 215 mm x 160 mm x 350 mm, 16 kg |
| Product Page | TBJT01 | TBJT02 | TBJT03 | TBJT04 |
Bulk Current Injection Probes
Bulk Current Injection Probes are used to inject RF-current into cables of electrical equipment to test the susceptibility against radiated electromagnetic energy. Tekbox BCI-probes can be clamped around wire bundles with up to 27 mm. They are designed to meet the specifcations of the standards IC 61000-4-6 (domestic and industrial products) and ISO 11452-4 (automotive products).
Tekbox supplies suitable wideband power amplifiers to drive the BCI probes:
TBMDA-CDN25 for immunity tests according to IC 61000-4-6
TBMDA-BCI25 for immunity tests according to ISO 11452-4
The calibration fixture TBBCI1-CAL is suitable for both BCI-probe models
![]() | ![]() | ![]() | ![]() |
|
|---|---|---|---|---|
| Model | TBBCI1-200K280 | TBBCI1-300K420-HV | TBBCI1-800K420 | TBBCI1-CAL |
| Frequency range | 150 kHz – 230 MHz | 300 kHz – 400 MHz | 1 MHz – 400 MHz | 150 kHz – 400 MHz |
| Coupling loss | 8 dB typical | 5 dB typical | 5 dB typical | – |
| Maximum RF input power | 50W continuous 100W short time | 50W continuous 100W short time | 50W continuous 100W short time | 500 W |
| Aperture diameter | 27 mm | 27 mm | 27 mm | – |
| Outer dimensions | 92 x 76 mm | 92 x 76 mm | 92 x 76 mm | 200 × 150 × 140 mm |
| Application / Standard | BCI probe for IEC / ISO 61000-6-4 | BCI probe for ISO 11452-4; MIL-STD-461 CS114, GJB 151B-2013, DO-160 | BCI probe for IEC / ISO 11452-4 | BCI probe calibrator for IC / ISO 61000-6-4 IEC / ISO 11452-4 |
| Product Page | TBBCI1-200K280 | TBBCI1-300K420-HV | TBBCI1-800K420 | TBBCI1-CAL |
Bias Tee
![]() |
|
|---|---|
| Model | TBBT01 |
| Usable frequency range | 5 kHz – 1.2 GHz |
| RF path insertion loss | <1 dB typ. in the range 10 kHz – 1 GH < 1.5 dB in the range 5 kHz – 1.2 GHz |
| VSWR | 1 < VSWR < 2 in the range 5 kHz to 1 GHz |
| Characterized frequency range | 1 kHz -3 GHz |
| RF power handling | 50 W from 5 kHz – 1 GHz |
| Operating voltage range | max. ±100 V |
| Operating current range | ± 5A DC continuous, max. ± 15 A DC |
| Product Page | TBBT01 |
Trans-conductance Amplifier/Current Injector
![]() |
|
|---|---|
| Model | TBRFCI1 |
| Frequency Range | DC – 50 MHz, useable up to 100 MHz |
| Transconductance | 0.1 A/V, 1 A/V |
| Product Page | TBRFCI1 |